Mechanisms

Mainly based on the APA concept, the CEDRAT Group has developed different mechanisms in order to fulfill its customers' requests for several degrees of freedom kinematics. These mechanisms take advantages of the APA concept offering a reliable, robust, precise and compact solution to the users.
These Standard mechanisms are currently available in order to meet various needs in terms of kinematics and force:

XY25XS    drawing 2D   data sheet   request for information
Description: The piezoelectric stage XY25XS is based on the APA25XS actuators. The compact XY25XS stage is well suited to integrated devices for fiber positioning, micro scanning.
Performance: Max displacement (µm): 20; Dimensions (mm): 18*50*50; Unloaded resonance frequency (Hz): 2200;
Available options: Strain Gages
Status: Standard
XY200M    drawing 2D   data sheet   request for information
Description: The piezoelectric stage XY200M is based on the APA200M actuators and posseses a high stiffness. Applications include mask positioning, atomic force or scanning tunneling microscopes.
Performance: Max No-load displacement (µm): 180; Dimensions (mm): 18*100*100; Resolution (nm): 1,8; Unloaded resonance frequency (Hz): 550;
Available options: Strain Gages; Eddy Current Sensors
Status: Standard
XYZ200M    drawing 2D   data sheet   request for information
Description: The piezoelectric stage XYZ200M is based on APA200M actuators and posseses a high stiffness. Applications include confocal microscopy, mask positioning, inspection
Performance: Max no load displacement (µm): 180; Max Z displacement (µm) 200; Height(mm): 44; Dimensions (mm): 100*100; Resolution (nm): 1,8; Unloaded resonance frequency (Hz): 380; Response time (ms): 1,32
Available options: Strain Gages; Eddy Current Sensors
Status: Standard
OPP120SM    drawing 2D   data sheet   request for information
Description: The objective piezo positionner OPP120SM is using the amplified piezo actuator from the CEDRAT Groupe standard range of actuator and an additional guiding to move vertically and accurately the objective.
Performance: Max No-load displacement(µm): 140; Dimensions(mm): 50*65*40; Resonance frequency(Hz): 440; Response time(ms): 1,14
Available options: Eddy Current Sensors
Status: Standard
FPS200M    drawing 2D   data sheet   request for information
Description: The Fast Piezo shutter developped by the CEDRAT Groupe in collaboration with EMBL (Dr. Cipriani) is based on standard amplified piezo actuators with a special optical head. It provides a compact and low jitter shutter solution for X ray beam.
Performance: Max No-load displacement (µm): 400; Dimensions (mm): 18,5*60*44; Unloaded resonance frequency (Hz): 900; Response time (ms): 0,56
Available options: Strain Gages; Vacuum; W interfaces
Status: Standard
FPS400M    drawing 2D   data sheet   request for information
Description: The FPS400M (derived from FPS200M) is based on standard amplified piezo actuators APA400M with a special optical head. The FPS400M is a compact, low jitter and high stroke shutter solution.
Performance: Max No-load displacement (µm): 800; Dimensions (mm): 18,5*60*44; Unloaded resonance frequency (Hz): 495; Response time (ms): 1,01
Available options: Strain Gages, Vacuum, W interfaces
Status: Standard
TT60SM    drawing 2D   data sheet   request for information
Description: The tilt translator is based on 2 APA60SM actuators. Two types of movement can be generated: translation and tilt.
Performance: Max No-load displacement(µm): 80; Angular displacement(mrad): 11; Dimensions(mm): 18*13*25; Angular Resolution(µrad): 0,1; Unloaded resonance frequency(Hz): 3000;
Available options: Strain Gages; Vacuum
Status: Standard
X240S       data sheet  
Description: The X240S is a linear stage for high straightness, flatness and accurate displacement. This linear stage is particularly relevant for fast and precise positioning of optics such as in optical delay line system.
Performance: Max no load displacement (µm): 240; Height(mm): 18.5; Dimensions (mm): 50*50; Resolution (nm): 2,4; Unloaded resonance frequency (Hz): 360; Response time (ms): 1,4
Available options: Strain Gages; Eddy Current Sensors; Vacuum
Status: Preliminary